Schedule ELECTRIC LIGHTING
In this Schedule, “general measurement points” mean, in relation to any space, those points which, measured at a height of 850 millimetres above the floor, fall on an imaginary line drawn vertically through the following points—
every point mid-way between every 2 adjacent lamps in that space;
every point mid-way between any lamp and any position on the boundary of that space to which that lamp is nearer than any other lamp; and
where any part of the space available for free movement is shielded from the direct rays of a lamp by a re-entrant angle formed in the boundary of that space, the central point of the space so shielded.
| Value | |
|---|---|
| Sleeping Rooms and Day Rooms | |
(1) At general measurement points | 50 lux |
(2) At every mirror | 200 lux |
(3) At every seat at a writing desk or table | 150 lux |
(4) At not less than half the seats (other than those mentioned in (3) above) in a sleeping room provided for use of more than one person | 150 lux |
| Mess rooms | |
(5) At general measurement points | 100 lux |
(6) At every table and sink | 150 lux |
| Recreation Rooms (including rooms for watching films and television, hobbies and games rooms) | |
(7) At general measurement points | 50 lux |
(8) At every recreational table | 100 lux |
(9) At every seat at a writing desk or table | 150 lux |
(10) At not less than half the seats other than those mentioned in (3) above | 150 lux |
| Hospital Wards | |
(11) At general measurement points | 50 lux |
(12) At any washbasin | 100 lux |
(13) At least one fixed lamp shall be installed in addition to the electric reading lamp required by regulation 13(4) to be provided at the head of each bed. | |
| Offices and Studies | |
(14) At general measurement points | 100 lux |
(15) At every seat at a writing desk or table | 200 lux |
| Sanitary Accommodation (including sanitary accommodation in hospitals) | |
(16) At general measurement points | 100 lux |
(17) At any mirror | 200 lux |
| Laundries | |
(18) At general measurement points | 100 lux |
| Drying Rooms | |
(19) At the centre of the space | 50 lux |
| Galleys (including bakeries and pantries) | |
(20) At working positions | 300 lux |
(21) The lights shall be so disposed as to ensure that food preparation tables, range tops serving tables and washing up sinks receive the maximum amount of light. | |
| Dry provision store rooms and cold store rooms | |
(22) At general measurement points | 100 lux |
(23) The lights shah be so disposed as to ensure that shelves and cupboards receive the maximum amount of light. | |
| Passageways, companionways and covered deck recreation spaces | |
(24) At general measurement points | 50 lux |
(25) A light shall be placed (1) at the head of each stairway, ladder and hatchway and (2) at or near the doors of lockers provided for oilskins or working clothes. | |