Paragraph 25
In the categories of spaces shown in regulation 132(2)(b)—
for category (5) there shall be substituted the following category—
“(5)service spaces of low riskare:
(i)in a ship constructed before 1st February 1992, lockers and storerooms having areas of less than 2 square metres, drying rooms and laundries;
(ii)in a ship constructed on or after 1st February 1992, lockers and storerooms not having provision for the storage of flammable liquids and having areas of less than 4 square metres, and drying rooms and laundries:”;
for category (9) there shall be substituted the following category—
“(9)service spaces of high riskare:
(i)in a ship constructed before 1st February 1992, galleys, pantries containing cooking appliances, paint and lamp rooms, lockers and storerooms having areas of 2 square metres or more, and workshops other than those forming part of the machinery spaces;
(ii)in a ship constructed on or after 1st February 1992, galleys, pantries containing cooking appliances, paint and lamp rooms, lockers and storerooms having areas of 4 square metres or more, spaces for the storage of flammable liquids, and workshops other than those forming part of the machinery spaces:”.