Regulation 3
In regulation 1(2):
in the definition of “’A’ Class division”, for “139°C” there shall be substituted “140°C”;
in the definition of “’B’ Class division”, for “139°C” there shall be substituted “140°C”;
in the definition of “cargo ship”, after “passenger ship” there shall be inserted “pleasure vessel or fishing vessel”;
after the definition of “equivalent material”, the following definition shall be inserted:
““Fire Test Procedures Code” means the International Code for Application of Fire Test Procedures, as adopted by the MSC Resolution MSC.61(67);”;
after the definition of “lightweight”, the following definition shall be inserted:
““low flame spread” means that the surface thus described will adequately restrict the spread of flame, this being determined in accordance with the Fire Test Procedures Code;”;
for the definition of “machinery spaces of Category A” there shall be substituted:
““machinery spaces of category A” are those spaces and trunks to such spaces which contain–
- (a)
internal combustion machinery used for main propulsion; or
- (b)
internal combustion machinery used for purposes other than main propulsion where such machinery has in the aggregate a total power output of not less than 375kW; or
- (c)
any oil-fired boiler or oil fuel unit;”;
for the definition of “non-combustible material” there shall be substituted:
““non-combustible material” means a material which neither burns nor gives off flammable vapours in sufficient quantity for self-ignition when heated to approximately 750°C, this being determined in accordance with the Fire Test Procedures Code. Any other material is a combustible material;”;
in the definition of “rooms containing furniture and furnishings of restricted fire risk”, after subparagraph (b) the following subparagraphs shall be substituted for subparagraphs (c), (d) and (e):
“(c)bedding components have qualities of resistance to the ignition and propagation of flame, determined in accordance with the Fire Test Procedures Code;
(d)in the case of ships constructed before 1st July 1998:
(i)all draperies, curtains and other suspended textile materials have qualities of resistance to the propagation of flame in accordance with the requirement of Type B performance of British Standard 5867: Part 2: 1980;
(ii)all surface floor coverings have qualities of resistance to the propagation of flame to the satisfaction of the Secretary of State; and
(iii)the upholstered parts of furniture have qualities of resistance to the ignition and propagation of flame to the satisfaction of the Secretary of State;
(e)in the case of ships constructed on or after 1st July 1998:
(i)all draperies curtains and other suspended textile materials have qualities of resistance to the propagation of flame determined in accordance with the Fire Tests Procedures Code;
(ii)all surface floor coverings have low flame spread; and
(iii)the upholstered parts of furniture have qualities of resistance to the ignition and propagation of flame, determined in accordance with the Fire Test Procedures Code;”;
for the definition “standard fire test” there shall be substituted the following:
““standard fire test” is one in which a specimen of the relevant bulkhead or deck is exposed in a test furnace to temperatures corresponding approximately to a standard time-temperature curve in accordance with the Fire Test Procedures Code;”; and
the definition of “surface spread of flame” shall be deleted.