(d)In every ship of Class VII of 2,000 tons or over the emergency fire pump shall—
(i)be capable of delivering at least one jet of water simultaneously from each of any two hydrants and hoses through nozzles which shall comply with the requirements of regulation 40(5)(b); and
(ii)meet the requirements or regulations 38(5).

---