  "heading": null,
  "text": "(1) This regulation applies to ships of Class VII of under 500 tons.\n(2) (a) Every such ship shall be provided with appliances in accordance with this regulation whereby at least one jet of water as required by these Regulations can reach any part of the ship normally accessible to the passenger or crew while the ship is being navigated, and any store room and any part of any cargo space when empty.\n(b) Every such ship shall be provided with at least one fire pump operated by power which shall be capable of delivering at least one jet of water from any fire hydrant, hose and nozzle provided in the ship, and which shall comply with the requirements of regulation 30.\n(c) In every such ship fitted with oil-fired boilers or internal combustion type propulsion machinery there shall be provided in a position outside the spaces containing such boilers or machinery an additional fire pump and its source of power and sea connection. If such a pump is operated by power it shall comply with the requirements of subparagraph (b) and if it is manually operated it shall be provided with a hose and a 10 millimetre diameter nozzle through which it shall be capable of producing a jet of water having a throw of not less than 6 metres which can be directed on to any part of the ship.\n(d) In every such ship there shall be provided a fire main, water service pipes and hydrants which shall comply with the requirements of regulation 31 and at least three fire hoses and nozzles which shall comply with regulation 32.\n(3) Every such ship shall be provided with at least three portable fire extinguishers so situated as to be readily available for use in the accommodation and service spaces.\n(4) In every ship to which this regulation applies there shall be provided for the protection of any space containing any oil-fired boiler, oil fuel settling tank or oil-fuel unit, at least one of the fire-extinguishing systems referred to in regulation 8.\n(5) In addition to the requirements of paragraph (4) there shall be provided—\n(a) in each boiler room and in each space which contains any part of any oil fuel installation, at least two portable fire extinguishers suitable for extinguishing oil fires;\n(b) in each firing space, a receptacle containing at least 0.3 cubic metre of sand or other dry material suitable for extinguishing oil fires together with a scoop for its distribution, or alternatively, an additional portable fire extinguisher suitable for extinguishing oil fires.\n(6) In every ship to which this regulation applies there shall be provided in any space containing internal combustion type machinery either—\n(a) one portable fire extinguisher suitable for extinguishing oil fires for each 74.6 kilowatts or part thereof of such machinery provided that no more than seven such extinguishers shall be required in any one space; or\n(b) two portable extinguishers suitable for extinguishing oil fires together with either—\n(i) one foam fire extinguisher of at least 45 litres capacity; or\n(ii) one carbon dioxide fire extinguisher of at least 16 kilogrammes capacity.\n(7) Every ship to which this regulation applies shall be provided with at least one fireman’s outfit which shall comply with the requirements of regulation 37 and which shall contain a breathing apparatus of the air-hose type.",
  "extent": "E+W+S+N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Reg. 17 in force at 11.5.1998, see reg. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1998/1011/regulation/17",
    "retrieved_at": "2026-10-29T11:32:26.653172+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}