# The Merchant Shipping (Life-Saving Appliances for Passenger Ships of Classes III to VI (A)) Regulations 1992, Paragraph 2.1: General


All lifeboats prescribed in this Part shall:
2.1.1 be constructed with proper workmanship and materials;
2.1.2 not be damaged in stowage throughout the air temperature range −30°C to +65°C;
2.1.3 be capable of operating throughout a seawater temperature range of −1°C to +30°C;
2.1.4 be rot-proof, corrosion-resistant, and not be unduly affected by seawater, oil or fungal attack;
2.1.5 .be resistant to deterioration from exposure to sunlight;
2.1.6 be of a highly visible colour on all parts where this will assist detection;
2.1.7 be fitted with retro-reflective material where it will assist in detection and the dimensions and location of the material shall be to the satisfaction of the Secretary of State;
2.1.8 be capable of satisfactory operation in a sea environment.

---
Source: https://www.legislation.gov.uk/uksi/1992/2359/schedule/1/paragraph/2.1 (the official version)