Means shall be provided for recharging all engine-starting, searchlight and, when fitted, radio batteries. Radio batteries shall not be used to provide power for engine starting. The electric power supply from the ship to any rigid rescue boat shall be at a voltage of not exceeding 55 volts direct current or 55 volts root mean square alternating current and shall be capable of being disconnected automatically at the rigid rescue boat embarkation station.