OpenLegislation

Paragraph 3.8 Inflated rescue boat propulsion

Original text. Later amendments are not shown.

Means shall be provided for recharging all engine-starting, searchlight and, when fitted, radio batteries. Radio batteries shall not be used to provide power for engine starting. Means shall be provided for recharging rescue boat batteries from the ship’s power supply. The electric power supply connection from the ship to any inflated rescue boat shall be at a voltage of not exceeding 55 volts direct current or 55 volts root mean square alternating current and shall be capable of being disconnected automatically at the inflated rescue boat embarkation station.