# The Merchant Shipping (Life-Saving Appliances for Passenger Ships of Classes III to VI (A)) Regulations 1992, Paragraph 3.1: Construction


A hydrostatic release unit used in the float-free arrangements shall be so constructed that:
3.1.1 the materials used are compatible so as to prevent malfunction of the unit; galvanising or other forms of metallic coating on parts of the release unit will not be accepted;
3.1.2 it has drains to prevent the accumulation of water in the hydrostatic chamber when the unit is in its normal position;
3.1.3 each part connected to the painter system has a strength not less than that required by the painter;
3.1.4 it can readily be removed for replacement or annual servicing.

---
Source: https://www.legislation.gov.uk/uksi/1992/2359/schedule/4/part/VI/paragraph/3.1 (the official version)
Page: https://openlegislation.uk/merchant-shipping-life-saving-appliances-for-passenger-ships-of-classes-iii-to-vi-a-regulations-1992/schedule-4/part-VI/paragraph-3.1