# The Merchant Shipping (Life-Saving Appliances for Passenger Ships of Classes III to VI (A)) Regulations 1992, Paragraph 3.3: Performance


A hydrostatic release unit shall:
3.3.1 function properly throughout an air temperature range of −30°C to +65°C;
3.3.2 function properly throughout a seawater temperature range of −1°C to +30°C;
3.3.3 automatically release the liferaft at a depth of not more than 4 metres;
3.3.4 not release prematurely when seas wash over the unit;
3.3.5 be capable of releasing a liferaft when the stowage is:
3.3.5.1. horizontal;
3.3.5.2 tilted 45° and 100° with the hydrostatic release unit at the upper side;
3.3.5.3 tilted 45° and 100° with the hydrostatic release unit at the lower side;
3.3.5.4 vertical.

---
Source: https://www.legislation.gov.uk/uksi/1992/2359/schedule/4/part/VI/paragraph/3.3 (the official version)
Page: https://openlegislation.uk/merchant-shipping-life-saving-appliances-for-passenger-ships-of-classes-iii-to-vi-a-regulations-1992/schedule-4/part-VI/paragraph-3.3
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.