Paragraph 1.2 General
The system shall:
be constructed with proper workmanship and materials;
not be damaged in stowage throughout a temperature range of −30°C to +65°C;
be capable of operating throughout an air temperature range of −30°C to +65°C, and a seawater temperature range of −1°C to +30°C;
where applicable be rot-proof, corrosion-resistant and not be unduly affected by seawater, oil or fungal attack;
be resistant to deterioration from exposure to sunlight;
be of highly visible colour on all parts that will assist detection;
be fitted with retro-reflective material where it will assist detection;
be sited clear of propellers and stabilisers;
be capable of removal for annual servicing;
be fitted with float free facilities complying with the requirements of Part VI of Schedule 4 on those parts of the system intended for use as inflatable survival equipment;
be provided with a gas inflation arrangement complying with the requirements of Part VIII of Schedule 4 which will by a single action rapidly deploy and inflate the system;
be provided with an additional gas supply of capacity at least 50% of that required to inflate the system so that any loss of pressure sustained during a deployment can rapidly be replenished;
if the inflation system includes air aspiration be provided with a means of protecting the aspirator from the danger of damage and the ingress of water; and
be capable of satisfactory operation in a seaway.