Paragraph 7.1 Static load test
Each davit, and its attachments, shall, with its arm in any position which gives a maximum stress concentration be capable of withstanding a static test load, in a direction simulating a 20° list or such greater angle as required by paragraph 2.1 of Part I of this Schedule and 10° trim, of not less than 2.2 times that part of the working load supported by the arm, or attachment.