OpenLegislation

Regulation 14 Oil filtering equipment and oil discharge monitoring and control system

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

(1)

Subject to paragraphs (3) and (7), every ship of 400 GT and above but less than 10,000 GT shall be fitted with oil filtering equipment complying with paragraph (5); and any such ship which carries ballast water in its bunker fuel tanks—

(a)
(i)

in addition, shall be provided with an alarm device and the means for automatically stopping and discharge of oily mixture when the oil content in the effluent exceeds 15 ppm complying with the specifications referred to in paragraph (6); and

(ii)

shall not discharge such ballast water into the sea unless using that equipment and a record of any such discharge shall made in the Oil Record Book; or

(b)

shall discharge the ballast water to reception facilities.

(2)

Subject to paragraphs (2) and (6), every ship which is of 10,000 GT and above shall be provided with—

(a)

oil filtering equipment complying with paragraph (5); and

(b)

oil content measuring equipment fitted with an 15ppm alarm device and with arrangements for automatically stopping any discharge of oily mixture when the oil content in the effluent exceeds 15 ppm, both complying with paragraph (6).

(3)

The Secretary of State may waive the requirements in paragraphs (1) and (2) if a ship is engaged exclusively on voyages within special areas and—

(a)

it is fitted with a holding tank having a volume adequate for the retention on board of all oily bilge water;

(b)

all oily bilge water is retained on board for subsequent discharge to reception facilities;

(c)

adequate reception facilities are available to receive such oily bilge water in a sufficient number of ports or terminals that the ship calls at;

(d)

the IOPP Certificate, when required, is endorsed to the effect that the ship is exclusively engaged on voyages within special areas; and

(e)

the relevant entries are recorded in the Oil Record Book.

(4)

Subject to paragraph (7), every ship which is of less than 400 GT shall, so far as reasonably practicable be constructed to ensure that oil or oily mixtures are retained on board and discharged to reception facilities or, if oil or oily mixtures are to be discharged into the sea, are so discharged in accordance with the requirements of regulation 12(2).

(5)

Oil filtering equipment shall be of an approved design in accordance with the specification for such equipment set out in the Recommendations on International Performance and Test Specifications for Oily Water Separating Equipment and Oil Content Meters.

(6)

Oil content measuring equipment and alarm device shall be of an approved design in accordance with the specification for such equipment set out in the Recommendations on International Performance and Test Specifications for Oily Water Separating Equipment and Oil Content Meters, and the arrangements for automatically stopping any discharge shall be of an approved design.

(7)

A ship delivered before 6th July 1993 need not comply with the foregoing requirements before 6th July 1998; but, if the ship does not so comply before that date, it shall be fitted with oily-water separating equipment which is such as to ensure that any oily mixture discharged into the sea after passing through the equipment has an oil content not exceeding 100 ppm.