# The Merchant Shipping (Radio) (Fishing Vessels) Regulations 1999, Regulation 16: Sources of energy


(1) There shall be available at all times while the fishing vessel is at sea a supply of electrical energy which is sufficient to operate the radio installations and to charge any batteries used as part of a reserve source or sources of energy for the radio installations.
(2) A reserve source or sources of energy shall be provided on every fishing vessel to supply radio installations used for the purpose of conducting distress and safety radio communications, in the event of failure of the fishing vessel’s main and emergency sources of electrical power.
(3) Subject to the following paragraphs of this regulation, the reserve source or sources of energy must be capable of simultaneously operating the VHF radio installation required by regulation 10(a) and, as appropriate for the sea area or sea areas for which the fishing vessel is equipped, either–
(a) the MF radio installation required by regulation 12(1)(a),
(b) the MF/HF radio installation required by paragraph (a) of ALTERNATIVE B in regulation 13(1) or by regulation 14, or
(c) the INMARSAT ship earth station required by paragraph (a) of ALTERNATIVE A in regulation 13(1),
and the additional loads mentioned in paragraphs (5), (6) and (9) of this regulation, for the minimum period specified in paragraph (4).
(4) For the purposes of paragraph (3) the minimum period is:
(a) in the case of a new fishing vessel–
(i) three hours, or
(ii) one hour, if the emergency source of electrical power complies fully with all relevant requirements of regulation 17 of Chapter IV of the Protocol, including the requirements to supply the radio installations, and is capable of serving for a period of at least six hours; or
(b) in the case of an existing fishing vessel–
(i) six hours, if the emergency source of electrical power is not provided or does not comply fully with all relevant requirements of regulation 17 of Chapter IV of the Protocol, including the requirements to supply the radio installations;
(ii) three hours, if the emergency source of electrical power complies fully with all relevant requirements of regulation 17 of Chapter IV of the Protocol, including the requirements to supply the radio installations; or
(iii) one hour, if the emergency source of electrical power complies fully with all relevant requirements of regulation 17 of Chapter IV of the Protocol, including the requirements of regulation 17 of Chapter IV of the Protocol, including the requirements to supply the radio installations, and is capable of serving for a period of at least six hours.
(5) Where there is an HF radio installation and an MF radio installation, the reserve source or sources of energy are not required to be capable of supplying them simultaneously.
(6) The reserve source or sources of energy shall be independent of the propelling power of the fishing vessel and the fishing vessel’s main electrical installation.
(7) Where, in addition to the VHF installation, two or more of the other radio installations referred to in paragraph (2) of this regulation can be connected to the reserve source or sources of energy, such sources shall be capable of simultaneously supplying, for the minimum period specified, as appropriate, in paragraph (4)(a) or (b) of this regulation the VHF radio installation and either–
(a) all other radio installations which can be connected to the reserve source or sources of energy at the same time; or
(b) if only one of the other radio installations can be connected to the reserve source or sources of energy at the same time as the VHF radio installation, whichever of the other radio installations will consume the most power.
(8) The reserve source or sources of energy may be used to supply the electrical lighting required by regulation 9(1)(d).
(9) Where a reserve source of energy consists of one or more rechargeable accumulator batteries–
(a) a means of automatically charging each battery shall be provided which is capable of recharging them to minimum capacity requirements within 10 hours; and
(b) the capacity of each battery shall be checked when the fishing vessel is not at sea and at intervals not exceeding 12 months.
(10) The siting and installation of a reserve source of energy consisting of one or more accumulator batteries shall be such as to ensure–
(a) the highest degree of service;
(b) a reasonable lifetime;
(c) reasonable safety;
(d) that battery temperatures remain within the manufacturer’s specifications whether under charge or idle; and
(e) that when fully charged, the one or more batteries will provide a reserve source of energy for at least the minimum period specified in paragraph (4) under all weather conditions.
(11) If an uninterrupted input of information from the fishing vessel’s navigational or other equipment to a radio installation required by this Part is needed to ensure its proper performance, means shall be provided to ensure the continuous input of such information in the event of failure of the fishing vessel’s main or emergency source of electrical power.
(12) For the purpose of calculating the required capacity of the reserve source of energy, the total current used in calculations shall be equal to the highest sum of all the radio installations which simultaneously can be connected to the source of energy, based on the following–
(a) the current consumption of the VHF receiver;
(b) one fifth of the current consumption of the VHF transmitter;
(c) the current consumption of an MF or MF/HF receiver and of the transmitter when it is in such a condition that operation of the “press to transmit" switch will make it ready for immediate transmission;
(d) one third of the current which may be drawn by an MF or MF/HF transmitter for speech transmission on the frequency at which the current consumption of the transmitter is at a maximum;
(e) the current consumption of an INMARSAT ship earth station when it is receiving transmissions;
(f) one quarter of the current which may be drawn by an INMARSAT ship earth station when it is transmitting in the mode at which the current consumption is at a maximum; and
(g) the total current consumption of all additional loads to which the reserve source may supply energy in times of distress or emergency.

---