  "url": "https://openlegislation.uk/meters-certification-regulations-northern-ireland-1998/schedule-1/paragraph-1n2",
  "json_url": "https://openlegislation.uk/meters-certification-regulations-northern-ireland-1998/schedule-1/paragraph-1n2.json",
  "legislation": "nisr/1998/444",
  "legislation_title": "Meters (Certification) Regulations (Northern Ireland) 1998",
  "legislation_url": "https://openlegislation.uk/meters-certification-regulations-northern-ireland-1998",
  "path": "schedule/1/paragraph/1n2",
  "kind": "paragraph",
  "number": "1",
  "heading": "Test loads",
  "text": "(1) Every repaired meter shall be tested at each of the loads specified in Table 2, except that test number 2 in that Table may be omitted.\n(2) Every new meter shall be calibrated and tested at a sufficient number of load points so as to ensure that meter errors are not greater than the limits specified in paragraph 9.\n(3) A test for starting will also be carried out on new meters in accordance with test number 7 of Table 2.\n(4) The ratio errors shall be determined for voltage transformers that are intended for use with meters but are not tested with a meter.\n(5) Current transformers intended for use with meters but not tested with a meter shall be tested from 5% to 120% of rated current.",
  "extent": "N.I.",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Sch. 1 para. 1n2 in operation at 1.2.1999, see reg. 1"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/nisr/1998/444/schedule/1/paragraph/1n2",
    "retrieved_at": "2026-10-29T02:21:52.995521+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}