OpenLegislation

Paragraph 4 Apparatus

Original text. Later amendments are not shown.

The following apparatus shall be used:—

(a)

a Lovibond “all purposes” comparator complete with stand for work in reflected light;

(b)

a Lovibond comparator disc A.P.T.W. or A.P.T.W.7;

(c)

two fused glass cells, 25 mm. depth;

(d)

a water bath or incubator capable of being maintained at 37.5degC. +/-0.5degC.;

(e)

a pipette to deliver 5.0 ml.;

(f)

a supply of 1.0 ml. straight-sided pipettes of an accuracy equal to N.P.L. Grade B;

(g)

a 1,000 ml. graduated flask;

(h)

a 100 ml. measuring cylinder or 100 ml. graduated flask;

(i)

a supply of 150 x 16 mm. test tubes conforming to B.S.3218: 1982, 150/16, with rubber stoppers to fit.