# The Natural Mineral Water, Spring Water and Bottled Drinking Water (England) Regulations 2007, Minimum levels of detection


Radionuclides
Limit of detection – Bq/l
Additional provision
U-238
0.02
U-234
0.02
Ra-226
0.04
Ra-228
0.02
The limit of detection in the second column only applies to the initial screening relating to the indicative dose for a new water source.
If initial analysis indicates that it is not plausible that Ra-228 will exceed 20% of its derived concentration, the food authority may increase the minimum limit of detection to 0.08 Bq/l for routine Ra-228 nuclide specific measurements, until a recheck is required following a change in the supply of the water that the food authority believes may influence the activity concentration of Ra-228 in the water. The food authority may increase the minimum level of detection back to 0.08 Bq/l again following the result of any recheck if the result of the analysis carried out in relation to that determines that the concentration of Ra-228 in the water does not exceed 20% of its derived concentration.
Pb-210
0.02
Po-210
0.01
C-14
20
Sr-90
0.4
Pu-239/Pu-240
0.04
Am-241
0.06
Co-60
0.5
Cs-134
0.5
Cs-137
0.5
I-131
0.5

---
Source: https://www.legislation.gov.uk/uksi/2007/2785/schedule/12/part/8/crossheading/minimum-levels-of-detection (the official version)