{
  "url": "https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-regulations-northern-ireland-2015/schedule-10/paragraph-1",
  "json_url": "https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-regulations-northern-ireland-2015/schedule-10/paragraph-1.json",
  "legislation": "nisr/2015/365",
  "legislation_title": "The Natural Mineral Water, Spring Water and Bottled Drinking Water Regulations (Northern Ireland) 2015",
  "legislation_url": "https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-regulations-northern-ireland-2015",
  "path": "schedule/10/paragraph/1",
  "kind": "paragraph",
  "number": "1",
  "heading": "Analysis of samples",
  "text": "(1) The district council must ensure that each sample is analysed in accordance with Annex III to Directive 98/83 and this Schedule.\n(2) For each parameter specified in the first column of Table 1 in Part 2 the method of analysis is specified in the second column of that table.\n(3) For each parameter specified in the first column of Table 2 in Part 2 the method of analysis is one that is capable of—\n(a) measuring concentrations and values with the trueness and precision specified in the second and third columns of that table; and\n(b) detecting the parameter at the limit of detection specified in the fourth column of that table.\n(4) For hydrogen ion, the method of analysis must be capable of measuring a value with a trueness of 0.2pH unit and a precision of 0.2 pH unit.\n(5) The method of analysis used for odour and taste parameters must be capable of measuring values equal to the parametric value with a precision of 1 dilution number at 25 ºC.\n(6) For the purpose of this paragraph—\n“limit of detection” is—\n(a)three times the relative within-batch standard deviation of a natural sample containing a low concentration of the parameter; or\n(b)five times the relative within-batch standard deviation of a blank sample;\n“precision” (the random error) is twice the standard deviation (within a batch and between batches) of the spread of results about the mean;\n“trueness” (the systematic error) is the difference between the mean value of the large number of repeated measurements and the true value.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/nisr/2015/365/schedule/10/paragraph/1",
    "retrieved_at": "2026-10-29T00:59:51.960438+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}