# The Natural Mineral Water, Spring Water and Bottled Drinking Water Regulations (Northern Ireland) 2015, Paragraph 4


If the following formula is satisfied, the indicative dose is considered to be less than the parametric value of 0.1 mSv and no further investigation is required—
∑i=1nCi(obs)Ci(der)≤1where
Ci(obs) = observed concentration radionuclide i
Ci(der) = derived concentration of radionuclide i
n = number of radionuclides detected

---
Source: https://www.legislation.gov.uk/nisr/2015/365/schedule/11/paragraph/4 (the official version)
Page: https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-regulations-northern-ireland-2015/schedule-11/paragraph-4
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.