# The Natural Mineral Water, Spring Water and Bottled Drinking Water Regulations (Northern Ireland) 2015, Part 3: Parametric values for indicator parameters

Extent: N.I.

Table C: Indicator Parameters
1 The water must not be aggressive.
2 Necessary only if the water originates from or is influenced by surface water.
3 This parameter need not be measured if the parameter Total Organic Carbon is analysed.
4 This parameter need not be measured for supplies of less than 10,000m3 a day.
Item
Parameter
Units of Measurement
Maximum Concentration or Value
1.
Aluminium
µg/l
200
2.
Ammonium
mg/l
0.50
3.
Chloride
mg/l
2501
4.
Clostridium perfringens (including spores)
number/100ml
02
5.
Colour
Acceptable to consumers and no abnormal change
. . .
6.
Conductivity
µS cm-1 at 20°C
25001
7.
Hydrogen ion concentration
pH units
4.5 (minimum)
9.5 (maximum)1
8.
Iron
µg/l
200
9.
Manganese
µg/l
50
10.
Odour
Acceptable to consumers and no abnormal change
. . .
11.
Oxidisability
mg/l O2
53
12.
Sulphate
mg/l
2501
13.
Sodium
mg/l
200
14.
Taste
Acceptable to consumers and no abnormal change
. . .
15.
Colony Count 22°
No abnormal change
16.
Coliform bacteria
number/250ml
0
17.
Total Organic Carbon
No abnormal change
4
18.
Turbidity
Acceptable to consumers and no abnormal change

---
Source: https://www.legislation.gov.uk/nisr/2015/365/schedule/7/part/3 (the official version)