{
  "url": "https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-wales-regulations-2015/schedule-11/part-2",
  "json_url": "https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-wales-regulations-2015/schedule-11/part-2.json",
  "legislation": "wsi/2015/1867",
  "legislation_title": "The Natural Mineral Water, Spring Water and Bottled Drinking Water (Wales) Regulations 2015",
  "legislation_url": "https://openlegislation.uk/natural-mineral-water-spring-water-and-bottled-drinking-water-wales-regulations-2015",
  "path": "schedule/11/part/2",
  "kind": "part",
  "number": "2",
  "heading": "Methods of analysis and performance characteristics",
  "text": "Table 1\nDerived concentrations for radioactivity\n1 This table allows only for the radiological properties of uranium, not for its chemical toxicity.\nOrigin\nNuclide\nDerived concentration\nNatural\nU-2381\n3.0 Bq/l\nU-2341\n2.8 Bq/l\nRa-226\n0.5 Bq/l\nRa-228\n0.2 Bq/l\nPb-210\n0.2 Bq/l\nPo-210\n0.1 Bq/l\nArtificial\nC-14\n240 Bq/l\nSr-90\n4.9 Bq/l\nPu-239/Pu-240\n0.6 Bq/l\nAm-241\n0.7 Bq/l\nCo-60\n40 Bq/l\nCs-134\n7.2 Bq/l\nCs-137\n11 Bq/l\nI-131\n6.2 Bq/l\nTable 2\nPerformance characteristics and methods of analysis\n1 The limit of detection is calculated according to the ISO standard 11929: Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionising radiation – Fundamentals and application, with probabilities of errors of 1st and 2nd kind of 0.05 each.\n2 Measurement uncertainties are calculated and reported as complete standard uncertainties, or as expanded standard uncertainties with an expansion factor of 1.96, according to the ISO Guide for the Expression of Uncertainty in Measurement.\n3 The limit of detection for tritium and for radon is 10% of its parametric value of 100 Bq/l.\n4 The limit of detection for gross alpha activity and gross beta activities are 40% of the screening values of 0.1 and 1.0 Bq/l respectively.\n5 This limit of detection applies only to initial screening for indicative dose for a new water source. If initial checking indicates that it is not plausible that Ra-228 exceeds 20% of the derived concentration, the limit of detection may be increased to 0.08 Bq/l for routine Ra-228 nuclide specific measurements, until a subsequent re-check is required.\nParameters and radionuclides\nLimit of detection 12\nTritium\n10 Bq/l 3\nRadon\n10 Bq/l 3\ngross alpha activity\ngross beta activity\n0.04 Bq/l 4\n0.4 Bq/l 4\nU-238\n0.02 Bq/l\nU-234\n0.02 Bq/l\nRa-226\n0.04 Bq/l\nRa-228\n0.02 Bq/l 5\nPb-210\n0.02 Bq/l\nPo-210\n0.01 Bq/l\nC-14\n20 Bq/l\nSr-90\n0.4 Bq/l\nPu-239/Pu-240\n0.04 Bq/l\nAm-241\n0.06 Bq/l\nCo-60\n0.5 Bq/l\nCs-134\n0.5 Bq/l\nCs-137\n0.5 Bq/l\nI-131\n0.5 Bq/l",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/wsi/2015/1867/schedule/11/part/2",
    "retrieved_at": "2026-10-28T23:32:29.204102+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}