# The Noise Emission in the Environment by Equipment for use Outdoors Regulations 2001, 


Manufacturers or their authorised representatives in the Union shall determine the surface sound pressure level at least three times. If at least two of the determined values do not differ by more than 1 dB, further measurements will not be necessary. Where that is not the case, manufacturers or their authorised representatives in the Union shall continue the measurements until they obtain two values that differ by no more than 1 dB. The A-weighted surface sound pressure level that manufacturers or their authorised representatives in the Union are to use for calculating the sound power level shall be the arithmetic mean of the two highest values that do not differ by more than 1 dB.
Where possible, manufacturers or their authorised representatives in the Union shall take the noise measurements at all the microphone positions simultaneously. This is especially important for dynamic tests. Where that is not possible, manufacturers or their authorised representatives in the Union shall take special care to ensure stable conditions in the test environment and to minimise the risks of including undesired variations in the noise emitted by the machine or by any other factors, including background noise and wind speed.

---
Source: https://www.legislation.gov.uk/uksi/2001/1701/schedule/6/part/A/crossheading/2 (the official version)