OpenLegislation

Paragraph 2 Units of mass

Original text. Later amendments are not shown.

Accuracy classes

2.1.

The following accuracy class have been defined:

Ispecial
IIhigh
IIImedium
IIIIordinary

The Specifications of these classes are given in Table 1.

Table 1

Accuracy classes

Minimum capacity (Min)

Number of Verification scale intervals

n=Maxe
ClassVerification scale interval (e)minimum valueminimum valuemaximum value
I0,001 g ≤e100 e50 000—
II0,001 g ≤e ≤0,05 g20 e100100 000
0,1 g ≤e50 e5 000100 000
III0,1 g ≤e ≤2 g20 e10010 000
5 g ≤e20 e50010 000
IIII5 g ≤e10 e1001 000

The minimum capacity is reduced to 5e for instruments in classes II and III for determining a conveying tariff.

2.2.

Scale intervals

2.2.1.

The actual scale interval (d) and the verification scale interval (e) shall be in the form:1 × 10k, 2 × 10k, or 5 × 10k mass units,

k being any integer or zero.

2.2.2.

For all instruments other than those with auxiliary indicating devices: d = e

2.2.3.

For instruments with auxiliary indicating devices the following conditions apply:

  • e = 1 × 10kg

  • d < e ≤ 10d

  • except for instruments of class I with d < 10−4g, for which e = 10−3g.

Notes on Schedule 2

Footnotes

f1