# The Non-Road Mobile Machinery (Emission of Gaseous and Particulate Pollutants) Regulations 1999, Paragraph 2.9.1: DEFINITIONS, SYMBOLS AND ABBREVIATIONS


Symbols for test parameters
Symbol
Unit
Term
AP
m2
Cross sectional area of the isokinetic sampling probe
AT
m2
Cross sectional area of the exhaust pipe
aver
Weighted average values for:
m3/h
—volume flow
kg/h
—mass flow
CI
–
Carbon 1 equivalent hydrocarbon
conc
ppm Vol%
Concentration (with suffix of the component nominating)
concc
ppm Vol%
Background corrected concentration
concd
ppm Vol%
Concentration of dilution air
DF
–
Dilution factor
fa
–
Laboratory atmospheric factor
FFH
Fuel specific factor used for the calulations of wet concentrations from dry concentrations hydrogen to carbon ratio
GAIRW
kg/h
Intake air mass flow rate on wet basis
GAIRD
kg/h
Intake air mass flow rate on dry basis
GDILW
kg/h
Dilution air mass flow rate on wet basis
GEDFW
kg/h
Equivalent diluted exhaust gas mass flow rate on wet basis
GEXHW
kg/h
Exhaust gas mass flow rate on wet basis
GFUEL
kg/h
Fuel mass flow rate
GTOTW
kg/h
Diluted exhaust gas mass flow rate on wet basis
HREF
g/kg
Reference value of absolute humidity 10.71 g/kg for calculation of NOX and particulate humidity correction factors
Ha
g/kg
Absolute humidity of the intake air
Hd
g/kg
Absolute humidity of the dilution air
i
–
Subscript denoting an individual mode
KH
–
Humidity correction factor for NOX
Kp
–
Humidity correction factor for particulate
KW,a
–
Dry to wet correction factor for the intake air
KW,d
–
Dry to wet correction factor for the dilution air
KW,e
–
Dry to wet correction factor for the diluted exhaust gas
KW,r
–
Dry to wet correction factor for the raw exhaust gas
L
%
Percent torque related to the maximum torque for the test speed
mass
g/h
Subscript denoting emissions mass flow rate
MDIL
kg
Mass of the dilution air sample passed through the particulate sampling filters
MSAM
kg
Mass of the diluted exhaust sample passed through the particulate sampling filters
Md
mg
Particulate sample mass of the dilution air collected
Mf
mg
Particulate sample mass collected
Pa
kPa
Saturation vapour pressure of the engine intake air (ISO 3046:
Psy = PSY; test ambient)
PB
kPa
Total barometric pressure (ISO 3046:
Px = PX Site ambient total pressure
Py = PY Test ambient total pressure)
Pd
kPa
Saturation vapour pressure of the dilution air
Ps
kPa
Dry atmospheric pressure
P
kW
Power, brake uncorrected
PAE
kW
Declared total power absorbed by auxiliaries fitted for the test which are not required by paragraph 2.4 of this Annex
PM
kW
Maximum measured power at the test speed under test conditions (see Annex VI, Appendix 1)
Pm
kW
Power measured at the different test modes
q
–
Dilution ratio
r
–
Ratio of cross sectional areas of isokinetic probe and exhaust pipe
Ra
%
Relative humidity of the intake air
Rd
%
Relative humidity of the dilution air
Rf
–
FID response factor
S
kW
Dynamometer setting
Ta
K
Absolute temperature of the intake air
TD
K
Absolute dewpoint temperature
Tref
K
References temperature (of combustion air: 298 K)
VAIRD
m3/h
Intake air volume flow rate on dry basis
VAIRW
m3/h
Intake air volume flow rate on wet basis
VDIL
m3
Volume of the dilution air sample passed through the particulate sample filters
VDILW
m3/h
Dilution air volume flow rate on wet basis
VEDFW
m3/h
Equivalent diluted exhaust gas volume flow rate on wet basis
VEXHD
m3/h
Exhaust gas volume flow rate on dry basis
VEXHW
m3/h
Exhaust gas volume flow rate on wet basis
VSAM
m3
Volume of sample through particulate sampling filters
VTOTW
m3/h
Diluted exhaust gas volume flow rate on wet basis
WF
–
Weighting factor
WFE
–
Effective weighting factor

---
Source: https://www.legislation.gov.uk/uksi/1999/1053/schedule/1/paragraph/2.9.1 (the official version)
Page: https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-1/paragraph-2.9.1
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.