{
  "url": "https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-3/paragraph-3.4",
  "json_url": "https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-3/paragraph-3.4.json",
  "legislation": "uksi/1999/1053",
  "legislation_title": "The Non-Road Mobile Machinery (Emission of Gaseous and Particulate Pollutants) Regulations 1999",
  "legislation_url": "https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999",
  "path": "schedule/3/paragraph/3.4",
  "kind": "paragraph",
  "number": "3.4",
  "heading": "Adjustment of the dilution ratio",
  "text": "The particulate sampling system shall be started and running on bypass for the single filter method (optional for the multiple filter method). The particulate background level of the dilution air may be determined by passing dilution air through the particulate filters. If filtered dilution air is used, one measurement may be done at any time prior to, during, or after the test. If the dilution air is not filtered, measurements at a minimum of three points, after the starting, before the stopping, and at a point near the middle of the cycle, are required, and the values averaged.\nThe dilution air shall be set to obtain a maximum filter face temperature of 325 K (52°C) or less at each mode. The total dilution ratio shall not be less than four.\nFor the single filter method, the sample mass flow rate through the filter shall be maintained at a constant proportion of the dilute exhaust mass flow rate for full flow systems for all modes. This mass ratio shall be within ±5%, except for the first 10 seconds of each mode for systems without bypass capability. For partial flow dilution systems with single filter method, the mass flow rate through the filter shall be constant within ±5% during each mode, except for the first 10 seconds of each mode for systems without bypass capability.\nFor CO2 or NOX concentration controlled systems, the CO2 or NOX content of the dilution air must be measured at the beginning and at the end of each test. The pre and post test backround CO2 or NOX concentration measurements of the dilution air must be within 100 ppm or 5 ppm of each other, respectively.\nWhen using a dilute exhaust gas analysis system, the relevent background concentrations shall be determined by sampling dilution air into a sampling bag over the complete test sequence.\nContinuous (non bag) background concentration may be taken at the minimum of three points, at the beginning, at the end, and a point near the middle of the cycle and averaged. At the manufacturer’s request background measurements may be omitted.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1999/1053/schedule/3/paragraph/3.4",
    "retrieved_at": "2026-10-29T10:51:33.224449+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}