  "url": "https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-5/crossheading-partial-flow-dilution-system-with-co2-concentration-measurement-carbon-balance-and-total-sampling",
  "json_url": "https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-5/crossheading-partial-flow-dilution-system-with-co2-concentration-measurement-carbon-balance-and-total-sampling.json",
  "legislation": "uksi/1999/1053",
  "legislation_title": "The Non-Road Mobile Machinery (Emission of Gaseous and Particulate Pollutants) Regulations 1999",
  "legislation_url": "https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999",
  "path": "schedule/5/crossheading/partial-flow-dilution-system-with-co2-concentration-measurement-carbon-balance-and-total-sampling",
  "kind": "crossheading",
  "number": "Figure 7",
  "heading": "Partial flow dilution system with CO2 concentration measurement, carbon balance and total sampling",
  "text": "Raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the sampling probe SP and the transfer tube TT. The CO2 concentrations are measured in the diluted exhaust gas and in the dilution air with the exhaust gas analyser(s) EGA. The CO2 and fuel flow GFUELsignals are transmtted either to the flow controller FC2, or to the flow controller FC3 of the particulate sampling system (see Figure 14), FC2 controls the pressure blower PB, while FC3 controls the particulate sampling system (see Figure 14), thereby adjusting the flows into and out of the system so as to maintain the desired exhaust split and dilution ratio in DT. The dilution ratio is calculated from the CO2 concentrations and GFUELusing the carbon balance assumption.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/1999/1053/schedule/5/crossheading/partial-flow-dilution-system-with-co2-concentration-measurement-carbon-balance-and-total-sampling",
    "retrieved_at": "2026-10-29T10:51:33.224449+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}