# The Non-Road Mobile Machinery (Emission of Gaseous and Particulate Pollutants) Regulations 1999, Partial flow dilution system with isokinetic probe and fractional sampling (PB control)


Raw exhaust gas is transferred from the exhaust pipe EP to the dilution tunnel DT through the transfer tube TT by the isokinetic sampling probe ISP. The differential pressure of the exhaust gas between exhaust pipe and inlet to the probe is measured with the pressure transducer DPT. This signal is transmitted to the flow controller FC1 that controls the pressure blower PB to maintain a differential pressure of zero at the tip of the probe. This is done by taking a small fraction of the dilution air whose flow rate has already been measured with the flow measurement device FM1, and feeding it to TT by means of pneumatic orifice. Under these conditions, exhaust gas velocities in EP and ISP are identical, and the flow through ISP and TT is a constant fraction (split) of the exhaust gas flow. The split ratio is determined from the cross sectional areas of EP and ISP. The dilution air is sucked through DT by the suction blower SB, as the flow rate is measured with FM1 at the inlet to DT. The dilution ratio is calculated from the dilution air flow rate and the split ratio.

---
Source: https://www.legislation.gov.uk/uksi/1999/1053/schedule/5/crossheading/partial-flow-dilution-system-with-isokinetic-probe-and-fractional-sampling-pb-control (the official version)
Page: https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-5/crossheading-partial-flow-dilution-system-with-isokinetic-probe-and-fractional-sampling-pb-control
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.

