# The Non-Road Mobile Machinery (Emission of Gaseous and Particulate Pollutants) Regulations 1999, Paragraph 1.1.1: Gaseous exhaust components CO, CO2, HC, NOX


An analytical system for the determination of the gaseous emissions in the raw or diluted exhaust gas is described based on the use of:
HFID analyser for the measurement of hydrocarbons,
NDIR analysers for the measurement of carbon monoxide and carbon dioxide,
HCLD or equivalent analyser for the measurement of nitrogen oxide.
For the raw exhaust gas (see Figure 2), the sample for all components may be taken with one sampling probe or with two sampling probes located in close proximity and internally split to the different analysers. Care must be taken that no condensation of exhaust components (including water and sulphuric acid) occurs at any point of the analytical system.
For the diluted exhaust gas (see Figure 3), the sample for the hydrocarbons shall be taken with another sampling probe than the sample for the other components. Care must be taken that no condensation of exhaust components (including water and sulphuric acid) occurs at any point of the analytical system.

---
Source: https://www.legislation.gov.uk/uksi/1999/1053/schedule/5/paragraph/1.1.1 (the official version)
Page: https://openlegislation.uk/non-road-mobile-machinery-emission-of-gaseous-and-particulate-pollutants-regulations-1999/schedule-5/paragraph-1.1.1