  "heading": "Amendment of the Pressure Equipment Regulations 1999",
  "text": "For the definition of “fluid in Group 1” substitute the following definition—\n““fluid in Group 1” means—\n(a) a substance or mixture—\n(i) as defined in Article 2(7) and (8) respectively of Regulation (EC) No 1272/2008 of the European Parliament and of the Council on classification, labelling and packaging of substances and mixtures (“the CLP Regulation”); and\n(ii) that is classified as hazardous in accordance with the following physical or health hazard classes laid down in Parts 2 and 3 of Annex I to the CLP Regulation—\n(aa) unstable explosives or explosives of Divisions 1.1, 1.2, 1.3, 1.4 and 1.5;\n(bb) flammable gases, categories 1 and 2;\n(cc) oxidising gases, category 1;\n(dd) flammable liquids, categories 1 and 2;\n(ee) flammable liquids, category 3 where the maximum allowable temperature is above the flashpoint;\n(ff) flammable solids, categories 1 and 2;\n(gg) self-reactive substances and mixtures, types A to F;\n(hh) pyrophoric liquids category 1;\n(ii) pyrophoric solids, category 1;\n(jj) substances and mixtures which in contact with water emit flammable gases, categories 1, 2 and 3;\n(kk) oxidising liquids, categories 1, 2 and 3;\n(ll) oxidising solids, categories 1, 2 and 3;\n(mm) organic peroxides, types A to F;\n(nn) acute oral toxicity, categories 1 and 2;\n(oo) acute dermal toxicity, categories 1 and 2;\n(pp) acute inhalation toxicity, categories 1, 2 and 3;\n(qq) specific target organ toxicity – single exposure, category 1; or\n(b) a substance or mixture contained in pressure equipment with a maximum allowable temperature TS which exceeds the flashpoint of the fluid;”.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "OJ L 353, 31.12.2008, p.1."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2015/399/regulation/3",
    "retrieved_at": "2026-10-28T23:46:04.273264+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}