OpenLegislation

Paragraph 5

Original text. Later amendments are not shown.

A package shall be so designed that if it were at the maximum normal operating pressure and it were subjected to the tests specified in paragraphs 6–11 and 13–16 of Part III of Schedule 15, the level of strains in the containment system would not attain values which would adversely affect the package in such a way that it would fail to meet the applicable requirements.