# The Radioactive Material (Road Transport) (Great Britain) Regulations 1996, Paragraph 17: Water immersion test for packages containing irradiated nuclear fuel


The specimen shall be immersed under a head of water of at least 200 metres for a period of not less than one hour. For demonstration purposes, an external gauge pressure of at least 2 MPa shall be considered to meet these conditions.

---