Paragraph 4 Testing the integrity of the containment system, shielding and criticality safety
After the applicable tests specified in paragraphs 6–20 below:
(a)
Faults and damage shall be identified and recorded;
(b)
It shall be determined whether the integrity of the containment system and shielding has been retained to the extent required in Schedules 2, 7, 9, 11, 12 and 13 for the packaging under test; and
(c)
For packages containing fissile material, it shall be determined whether the assumptions made in paragraphs 1 to 6 of Schedule 7 regarding the most reactive configuration and degree of moderation of the fissile contents, of any escaped material, and of one or more packages are valid.