OpenLegislation

Paragraph C

Original text. Later amendments are not shown.

Applications for approval of all plant and (or) equipment employing electric traction shall additionally be accompanied by:

(a)

a line diagram showing the lines, the location of stations, bridges and level crossings, and the position of signals;

(b)

diagrams showing the traction supply arrangements including the location of outside supply points, bare feeders, the arrangement of substations, remote and local control and isolating switches, and neutral sections or conductor rail gaps;

(c)

a schedule of locations of proposed warning notices;

(d)

details of fencing where access is to be limited to any structure housing equipment for the supply and (or) control of electrical power.