  "url": "https://openlegislation.uk/restriction-of-the-use-of-certain-hazardous-substances-in-electrical-and-electronic-equipment-amendment-regulations-2023/regulation-2",
  "json_url": "https://openlegislation.uk/restriction-of-the-use-of-certain-hazardous-substances-in-electrical-and-electronic-equipment-amendment-regulations-2023/regulation-2.json",
  "legislation": "uksi/2023/658",
  "legislation_title": "The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment (Amendment) Regulations 2023",
  "legislation_url": "https://openlegislation.uk/restriction-of-the-use-of-certain-hazardous-substances-in-electrical-and-electronic-equipment-amendment-regulations-2023",
  "path": "regulation/2",
  "kind": "regulation",
  "number": "2",
  "heading": "Amendment of the Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012",
  "text": "(1) The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 are amended as follows.\n(2) In Schedule A2, in Table 1, for entries 1 to 9 substitute—\n“\n1\nMercury in single capped (compact) fluorescent lamps:\n1.1\nFor general lighting purposes < 30 W\n2.5 mg per burner\nAnnex 3, 1(a)\nall categories\n1st February 2024\n1.2\nFor general lighting purposes ≥ 30 W and < 50 W\n3.5 mg per burner\nAnnex 3, 1(b)\nall categories\n1st February 2024\n1.3\nFor general lighting purposes ≥ 50 W and < 150 W\n5 mg per burner\nAnnex 3, 1(c)\nall categories\n1st February 2024\n1.4\nFor general lighting purposes ≥ 150 W\n15 mg per burner\nAnnex 3, 1(d)\nall categories\n1st February 2024\n1.5\nFor general lighting purposes with circular or square structural shape and tube diameter ≤ 17 mm\n5 mg per burner\nAnnex 3, 1(e)\nall categories\n1st February 2024\n1.6\nFor general lighting purposes < 30 W with a lifetime ≥ 20,000 h\n3.5 mg per burner\nAnnex 3, 1(g)\nall categories\n1st February 2024\n1.7\nFor special purposes\n5 mg per burner\nAnnex 3, 1(f)-II\nall categories\n24th February 2025\n1.8\nFor lamps designed to emit mainly light in the ultraviolet spectrum\n5mg per burner\nAnnex 3, 1(f)- I\nall categories\n24th February 2027\n2\nMercury in double-capped linear fluorescent lamps for general lighting purposes:\n2.1\nTri-band phosphor with normal lifetime (< 25,000 h) and a tube diameter < 9 mm (e.g. T2)\n4 mg per lamp\nAnnex 3, 2(a)(1)\nall categories\n1st February 2024\n2.2\nTri-band phosphor with normal lifetime (< 25,000 h) and a tube diameter ≥ 9mm and ≤ 17 mm (e.g. T5)\n3 mg per lamp\nAnnex 3, 2(a)(2)\nall categories\n1st February 2024\n2.3\nTri-band phosphor with normal lifetime (< 25,000 h) and a tube diameter > 17mm and ≤ 28 mm (e.g. T8)\n3.5 mg per lamp\nAnnex 3, 2(a)(3)\nall categories\n1st February 2024\n2.4\nTri-band phosphor with normal lifetime (< 25,000 h) and a tube diameter > 28mm (e.g. T12)\n3.5 mg per lamp\nAnnex 3, 2(a) (4)\nall categories\n1st February 2024\n2.5\nTri-band phosphor with long lifetime (≥ 25,000 h)\n5 mg per lamp\nAnnex 3, 2(a) (5)\nall categories\n1st February 2024\n3\nMercury in other fluorescent lamps:\n3.1\nNon-linear tri-band phosphor lamps with tube diameter > 17 mm (e.g. T9)\n15 mg per lamp\nAnnex 3, 2(b)(3)\nall categories\n1st February 2024\n3.2\nFrom 2nd February 2024, non-linear tri-band phosphor lamps with tube diameter > 17 mm (e.g. T9)\n10 mg per lamp\nAnnex 3, 2(b)(3)\nall categories\n24th February 2025\n3.3\nLamps for other general lighting purposes and special purposes (e.g. induction lamps)\n15 mg per lamp\nAnnex 3, 2(b)(4)- I\nall categories\n24th February 2025\n3.4\nLamps emitting mainly light in the ultraviolet spectrum\n15 mg per lamp\nAnnex 3, 2(b)(4)- II\nall categories\n24th February 2027\n3.5\nEmergency lamps\n15 mg per lamp\nAnnex 3, 2(b)(4)- III\nall categories\n24th February 2027\n4\nMercury in cold cathode fluorescent lamps and external electrode fluorescent lamps (CCFL and EEFL) for special purposes used in EEE placed on the market before 24th February 2022:\n4.1\nShort length (≤ 500 mm)\n3.5 mg per lamp\nAnnex 3, 3(a)\nall categories\n24th February 2025\n4.2\nMedium length (> 500 mm and ≤ 1500 mm)\n5 mg per lamp\nAnnex 3, 3(b)\nall categories\n24th February 2025\n4.3\nLong length (> 1500 mm)\n13 mg per lamp\nAnnex 3, 3(c)\nall categories\n24th February 2025\n5\nMercury in other low pressure discharge lamps:\n5.1\nMercury in low pressure non-phosphor coated discharge lamps, where the application requires the main range of the lamp-spectral output to be in the ultraviolet spectrum\n15 mg per lamp\nAnnex 3, 4(a)- I\nall categories\n24th February 2027\n5.2\nMercury in other low pressure discharge lamps\n15 mg per lamp\nAnnex 3, 4(a)\nall categories\n1st February 2024\n6\nMercury in High Pressure Sodium (vapour) lamps for general lighting:\n6.1\nMercury in High Pressure Sodium (vapour) lamps for general lighting purposes in lamps with improved colour rendering index Ra > 80: P ≤ 105 W\n16 mg per burner\nAnnex 3, 4(b)\nall categories\n24th February 2027\n6.2\nMercury in High Pressure Sodium (vapour) lamps for general lighting purposes in lamps with improved colour rendering index Ra > 60: P ≤ 155 W\n30 mg per burner\nAnnex 3, 4(b)- I\nall categories\n1st February 2024\n6.3\nMercury in High Pressure Sodium (vapour) lamps for general lighting purposes in lamps with improved colour rendering index Ra > 60: 155 W < P ≤ 405 W\n40 mg per burner\nAnnex 3, 4(b)- II\nall categories\n1st February 2024\n6.4\nMercury in High Pressure Sodium (vapour) lamps for general lighting purposes in lamps with improved colour rendering index Ra > 60: P > 405 W\n40 mg per burner\nAnnex 3, 4(b)- III\nall categories\n1st February 2024\n7\nMercury in other High Pressure Sodium (vapour) lamps for general lighting purposes:\n7.1\nP ≤ 155 W\n20 mg per burner\nAnnex 3, 4(c)- I\nall categories\n24th February 2027\n7.2\n155 W < P ≤ 405 W\n25 mg per burner\nAnnex 3, 4(c)-II\nall categories\n24th February 2027\n7.3\nP > 405 W\n25 mg per burner\nAnnex 3, 4(c)-III\nall categories\n24th February 2027\n8\nMercury in metal halide lamps\nAnnex 3, 4(e)\nall categories\n24th February 2027\n9\nMercury in other discharge lamps:\n9.1\nMercury in high pressure mercury vapour lamps used in projectors where an output ≥ 200 lumen ANSI is required\nAnnex 3, 4(f)- II\nall categories\n24th February 2027\n9.2\nMercury in high pressure sodium lamps used for horticulture lighting\nAnnex 3, 4(f)- III\nall categories\n24th February 2027\n9.3\nMercury in lamps emitting light in the ultraviolet spectrum\nAnnex 3, 4(f)- IV\nall categories\n24th February 2027\n9.4\nMercury in other discharge lamps for special purposes not specifically mentioned in another entry in this Table\nAnnex 3, 4(f)-I\nall categories\n24th February 2025\n”.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "footnote",
      "label": "f1",
      "text": "S.I. 2012/3032, amended by S.I. 2020/1647, 2021/422, 2021/1395 and 2022/622. There are other amending instruments which are not relevant to these Regulations."
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2023/658/regulation/2",
    "retrieved_at": "2026-10-28T21:44:06.979385+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}