| 09-2 | The installation of 33kV and higher voltage power cables and associated auxiliary cables Amendment 1, 1995 to Issue 3, 1983 |
| 09-4 | 66kV and 132kV impregnated paper insulated oil-filled and gas-pressure type power cable systems Amendment 1, 1995 to Issue 3, 1991 |
| 09-6 | Auxiliary multicore and multipair cables Amendment 1, 1995 to Issue 6, 1988 |
| 09-7 | PVC insulated concentric service cables with stranded copper or solid aluminium phase conductors and copper concentric conductors Amendment 1, 1995 to Issue 4, 1981 |
| 09-9 | Polymeric insulated, combined neutral/earth (CNE) cables with solid aluminium phase conductors and concentric aluminium wire waveform neutral/earth conductor Amendment 1, 1995 to Issue 5, 1981 |
| 09-11 | Heat shrinkable insulating material for use with 600/1000V cables and accessories Amendment 1, 1995 to Issue 1, 1975 |
| 09-12 | Impregnated paper insulated corrugated aluminium sheathed 6350/11000 volt cable Amendment 1, 1995 to Issue 2, 1990 |
| 09-17 | Single core cables for use in substations having extruded insulation and rated voltages of 6350/11000 volts and 19000/33000 volts Amendment 1, 1995 Issue 2, 1991 |
| 26-3 | Hand held insulated tools for live working up to 1000 volts Amendment 1, 1995 to Issue 2, 1984 |
| 41-10 | Switchgear for use on 66 and 132kV distribution systems Issue 4, 1995 |
| 41-18 | Partial discharge testing of bushings, capacitors, instrument transformers and switchgear of rated voltage 7.2-420kV inclusive Issue 2, 1995 |
| 41-26 | Distribution switchgear for service up to 36kV (cable connected) Amendment 2, 1995 to issue 1, 1991 |
| 41-27 | Outdoor distribution switchgear for service up to 36kV (overhead conductor connected) Amendment 2, 1995 to Issue 1, 1991 |
| 43-91 | Stay strands and stay fittings for overhead lines Amendment 1, 1995 to Issue 4, 1984 |
| 43-96 | Fasteners and washers for wood pole and overhead lines Amendment 1, 1995 to Issue 2, 1986 |
| 43-103 | Low voltage overhead line temporary shrouding material Issue 1, 1995 |
| C55/4 | Insulated sheath power cable systems 1989 Amendment 1, 1995 |
| C64 | Testing procedure for approval of joints for cables generally to BEBS C5 1969 Amendment 4, 1995 |
| C79 | Type approval tests for connectors and terminations for aluminium conductors of insulated power cables 1972 Amendment 3, 1995 |
| C92 | Performance specification for pole top terminations on 6350/11000 Volt paper insulated cables 1987 |
| Part 1: Non-metallic pole boxes for mass-impregnated non-draining (MIND) solid type cables Amendment 1, 1995 |
| G12/3 | Requirements for the application of protective multiple earthing to low voltage networks |
| 1995 |
| G58/2 | Purchase, use, storage, inspection and maintenance of hand held insulated tools for live working up to 1000 volts 1995 |
| G59/1 | Recommendations for the connection of embedded generating plant to the Regional Electricity Companies' distribution systems 1991 Amendment 2, 1995 |
| L9/3 | Structural testing of wood poles prior to climbing or use as a personal support 1995 |
| S15 | Standard Schematic Diagrams |
| Part 1: Schematic Diagrams 1956 Amendment 1, 1995 |
| Part 2: Alarm Systems 1963 Amendment 1, 1995 |
| Part 3: Basic diagrams for voltage and current transformer secondary circuits 1967 Amendment 3, 1995 |
| ETR 113 | Notes of guidance for the protection of embedded generating plant up to 5 MW for operation in parallel with Public Electricity Suppliers' distribution systems Revision 1, 1995 |
| SMCC 004 | Notes of guidance on the safe working of third parties in close proximity to live low voltage overhead conductors 1995 |
| SMCC 006 | Notes of guidance on earthwire replacement with one circuit live in 132kV double circuit power lines 1995 |