  "url": "https://openlegislation.uk/town-and-country-planning-general-permitted-development-england-order-2015/schedule-2/part-7/crossheading-class-h-extensions-etc-of-industrial-and-warehouse/paragraph-H.1",
  "json_url": "https://openlegislation.uk/town-and-country-planning-general-permitted-development-england-order-2015/schedule-2/part-7/crossheading-class-h-extensions-etc-of-industrial-and-warehouse/paragraph-H.1.json",
  "legislation": "uksi/2015/596",
  "legislation_title": "The Town and Country Planning (General Permitted Development) (England) Order 2015",
  "legislation_url": "https://openlegislation.uk/town-and-country-planning-general-permitted-development-england-order-2015",
  "path": "schedule/2/part/7/crossheading/class-h-extensions-etc-of-industrial-and-warehouse/paragraph/H.1",
  "kind": "paragraph",
  "number": "H.1",
  "heading": "Development not permitted",
  "text": "Development is not permitted by Class H if—\n(a) the gross floor space of any new building erected would exceed—\n(i) for a building on article 2(3) land or on a site of special scientific interest, 100 square metres;\n(ii) in any other case, would exceed 200 square metres;\n(b) the gross floor space of the original building would be exceeded by more than—\n(i) in respect of an original building or a development on article 2(3) land, 10% or 500 square metres (whichever is lesser);\n(ii) in respect of an original building or a development on a site of special scientific interest, 25% or 1,000 square metres (whichever is the lesser);\n(iii) in any other case, 50% or 1,000 square metres (whichever is the lesser);\n(c) the height of any part of the new building erected would exceed—\n(i) if within 10 metres of a boundary of the curtilage of the premises, 5 metres;\n(ii) in all other cases, the height of the highest building within the curtilage of the premises or 15 metres, whichever is lower;\n(d) the height of the building as extended or altered would exceed—\n(i) if within 10 metres of a boundary of the curtilage of the premises, 5 metres;\n(ii) in all other cases, the height of the building being extended or altered;\n(e) any part of the development would be within 5 metres of any boundary of the curtilage of the premises;\n(f) the development would lead to a reduction in the space available for the parking or turning of vehicles; or\n(g) the development would be within the curtilage of a listed building.",
  "extent": null,
  "status": null,
  "version": "current",
  "annotations": [],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2015/596/schedule/2/part/7/crossheading/class-h-extensions-etc-of-industrial-and-warehouse/paragraph/H.1",
    "retrieved_at": "2026-11-05T03:36:20.788841+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}