# The Triton Knoll Offshore Wind Farm Order 2013, Paragraph 3: Detailed design parameters

Extent: E+W+S

(1) No wind turbine generator forming part of the authorised development shall—
(a) exceed a height of 220 metres when measured from LAT to the tip of the vertical blade;
(b) exceed a height of 140 metres when measured from LAT to the height of the centreline of the generator shaft forming part of the hub;
(c) exceed a rotor diameter of 180 metres;
(d) be less than a multiple of 4 times the rotor diameter from the nearest WTG in either direction perpendicular to the approximate prevailing wind direction (cross-wind) or be less than a multiple of 7 times the rotor diameter from the nearest WTG in either direction which is in line with the approximate prevailing wind direction (downwind);
(e) have a distance of less than 22 metres between the lowest point of the rotating blade of the wind turbine and MHWS or less than 27.4 metres between the lowest point of the rotating blade of the wind turbine and LAT.
(2) In sub-paragraph (1), references to the location of a wind turbine generator are references to the centre point of that turbine.

---