# The Urban Waste Water Treatment (England and Wales) Regulations 1994, Paragraph 5


The points of discharge of urban waste water shall be chosen, as far as possible, so as to minimise the effects on receiving waters.
TABLE 1
REQUIREMENTS FOR DISCHARGES FROM URBAN WASTE WATER TREATMENT PLANTS SUBJECT TO REGULATION 5(1) AND (2)
The values for concentration or for the percentage of reduction shall apply.
{s001} Reduction in relation to the load of the influent.
{s002} The parameter can be replaced by another parameter: total organic carbon (TOC) or total oxygen demand (TOD) if a relationship can be established between BOD5 and the substitute parameter.
Parameters
Concentration
Minimum percentage of reduction {s001}
Reference method of measurement
Biochemical oxygen demand (BOD5 at 20°C without nitrification {s002}
25 mg/l O2
70—90
Homogenized, unfiltered, undecanted sample. Determination of dissolved oxygen before and after five-day incubation at 20°+1°C, in complete darkness. Addition of a nitrification inhibitor
Chemical oxygen demand (COD)
125 mg/l O2
75
Homogenized, unfiltered, undecanted sample Potassium dichromate

---
Source: https://www.legislation.gov.uk/uksi/1994/2841/schedule/3/part/I/paragraph/5 (the official version)