  "heading": "Scheme design",
  "text": "(1) Subject to sub-paragraph (2), Works Nos. 1, 14, 21, 31 and 44 must be carried out in general accordance with the general arrangement plans.\n(2) The authorised development will not be in general accordance with the general arrangement plans if any departure from the general arrangement plans would give rise to any materially new or materially different environmental effects from those assessed in the environmental statement.\n(3) The authorised development must be designed in accordance with the parameters specified in Table 1 below and the works plans and implemented in accordance with approved plans and any other approvals given by the relevant planning authority pursuant to these requirements.\nTable 1 Work TypeParameterPart(s) of authorised developmentMaximum value(s) and unit\nAGIMaximum fenced area at the Immingham facilityWork No. 110,500m2\nAGIMaximum height of buildings and structures at the Immingham facility, excluding the vent stackWork No. 15m from ground level\nAGIMaximum height of the vent stack at the Immingham facilityWork No. 125m from ground level\nAGIMaximum height of fencing and gating at the Immingham facilityWork No. 13.2m from ground level\nAGIMaximum fenced area at the Theddlethorpe facilityWork No. 4413,500m2\nAGIMaximum height of buildings and structures at the Theddlethorpe facility, excluding the vent stackWork No. 445m from ground level\nAGIMaximum height of the vent stack at the Theddlethorpe facilityWork No. 4425m from ground level\nAGIMaximum height of fencing and gating at the Theddlethorpe facilityWork No. 443.2m from ground level\nBVSMaximum fenced area of each BVSWork Nos. 14, 21, 312,000m2\nBVSMaximum height of buildings and structuresWork Nos. 14, 21, 314m from ground level\nBVSMaximum height of fencing and gatingWork Nos. 14, 21, 313.2m from ground level\n(4) The buildings and structures identified in Table 1 must only be constructed within the area for the Work No. of which they form part as shown in the works plans.",
  "extent": "E+W",
  "status": null,
  "version": "enacted",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Sch. 2 para. 4 in force at 1.5.2025, see art. 1(2)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2025/509/schedule/2/paragraph/4",
    "retrieved_at": "2026-10-28T21:16:49.996360+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}