# The Water Intended for Human Consumption (Private Supplies) (Scotland) Regulations 2017, Paragraph 1

Extent: S

(1) Subject to paragraph 3, for a parameter in Table 1, the method of analysis used must, as a minimum, be capable of measuring concentrations equal to the parametric value for the parameter with—
(a) a limit of quantification of 30 % or less of the parametric value; and
(b) an uncertainty of measurement as specified in Table 1.
(2) The result of the analysis for a parameter in Table B or Table C must be expressed using at least the same number of significant figures as the parametric value for the parameter in the table.

---
Source: https://www.legislation.gov.uk/ssi/2017/282/schedule/4/part/B/paragraph/1n3 (the official version)
Page: https://openlegislation.uk/water-intended-for-human-consumption-private-supplies-scotland-regulations-2017/schedule-4/part-B/paragraph-1n3
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.