  "url": "https://openlegislation.uk/weighing-equipment-automatic-gravimetric-filling-instruments-regulations-2000/schedule-4/paragraph-3.11.2",
  "json_url": "https://openlegislation.uk/weighing-equipment-automatic-gravimetric-filling-instruments-regulations-2000/schedule-4/paragraph-3.11.2.json",
  "legislation": "uksi/2000/388",
  "legislation_title": "The Weighing Equipment (Automatic Gravimetric Filling Instruments) Regulations 2000",
  "legislation_url": "https://openlegislation.uk/weighing-equipment-automatic-gravimetric-filling-instruments-regulations-2000",
  "path": "schedule/4/paragraph/3.11.2",
  "kind": "paragraph",
  "number": "3.11.2",
  "heading": "Mounting",
  "text": "Filling instruments required to bear verification marks shall have a verification mark support, at the place provided for above, which shall ensure the conservation of the marks.\nWhen the mark is made with a stamp, this support may consist of a strip of lead or any other material with similar qualities, inserted into a plate fixed to the filling instrument or a cavity bored in the filling instrument itself.",
  "extent": "E+W+S",
  "status": null,
  "version": "current",
  "annotations": [
    {
      "type": "I",
      "label": "I1",
      "text": "Sch. 4 para. 3.11.2 in force at 17.7.2000, see reg. 1(1)"
    }
  ],
  "outstanding_effects": [],
  "provenance": {
    "source": "legislation.gov.uk",
    "source_url": "https://www.legislation.gov.uk/uksi/2000/388/schedule/4/paragraph/3.11.2",
    "retrieved_at": "2026-10-29T09:20:43.910403+00:00"
  },
  "licence": "Open Government Licence v3.0",
  "licence_url": "https://www.nationalarchives.gov.uk/doc/open-government-licence/version/3/",
  "attribution": "Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives."
}