# The Weighing Equipment (Filling and Discontinuous Totalising Automatic Weighing Machines) (Amendment) Regulations 1996, Regulation 13: Amendment


The principal Regulations are hereby further amended in Schedule 3, by the substitution for Table 2 of the following Table—
“DISCONTINUOUS TOTALISERS
Table 2
Class of accuracy of discontinuous totaliser
Limits of error relative to weight of material used in tests
In relation to passing as fit for use for trade
In relation to obliteration of the stamp
Class 0.2
Plus or minus 0.1%
Plus or minus 0.2%
Class 0.5
Plus or minus 0.25%
Plus or minus 0.5%
Class 1
Plus or minus 0.5%
Plus or minus 1%
Class 2
Plus or minus 1%
Plus or minus 2%
”

---