# The Weighing Equipment (Filling and Discontinuous Totalisting Automatic Weighing Machines) Regulations 1986, Paragraph 5


Before commencing material testing of a discontinuous totaliser, the inspector shall satisfy himself that the arrangements (which may include the use of a non-automatic weighing machine or an internal non-automatic weighing facility) to be used for determining the weight of material used in the testing will give a weight determination of each test load (determined in one or more weighing operations) to an accuracy equal to or better than—
(a) one-fifth of the prescribed limits of error for material testing; or
(b) in a case where the accuracy of such arrangements is assessed immediately before use, one-third of such prescribed limits.

---
Source: https://www.legislation.gov.uk/uksi/1986/1320/schedule/2/paragraph/5 (the official version)
Page: https://openlegislation.uk/weighing-equipment-filling-and-discontinuous-totalisting-automatic-weighing-machines-regulations-1986/schedule-2/paragraph-5
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.