Table 4

Maximum capacity “Max”Lower limit of the minimum load “Min”Scale interval “d”Number of scale intervals “n”Verification scale interval “e”

Notes

  1. 1.

    In the case of machines where the weight indicating or printing is in units of the imperial system the relevant capacity and verification scale interval shall be the amounts in imperial units which are equivalent to those specified in the Table in terms of g, kg and t.

  2. 2.

    Where the equivalent metric value for an imperial scale interval falls between ranges then the value shall be considered as belonging to the lower range.

Non-graduated machines
400g Max 2 kg10e5g
2kg Max10e Max400
Graduated machines
Non-self indicating machines
400g Max 2kg10d5g d 10g80 n 4005g
2kg Max 4t10d10g d 10kg100 n 400 Max400
2kg Max 10t10d5g d 10kg400 n 1000d
4t Max10d20kg d200 n 400 Max400
8t Max10d20kg d400 n 1000d
Self and semi-self indicating machines
400g Max 10t10d2g d 10kg60 n 1000d
4t Max10d20kg d200 n 1000d