OpenLegislation

Paragraph 17

Changes not yet applied. Later legislation changes this provision in ways not yet written into the text below:

The specifications for non-graduated and graduated Class IIII machines are given in Table 4.

Table 4

Maximum capacity “Max”Lower limit of the minimum load “Min”Scale interval “d”Number of scale intervals “n”Verification scale interval “e”

Notes

  1. 1.

    In the case of machines where the weight indicating or printing is in units of the imperial system the relevant capacity and verification scale interval shall be the amounts in imperial units which are equivalent to those specified in the Table in terms of g, kg and t.

  2. 2.

    Where the equivalent metric value for an imperial scale interval falls between ranges then the value shall be considered as belonging to the lower range.

Non-graduated machines
1 kg ≤ Max < 2 kg10 e5 g
2 kg ≤ Max10 e Max400
Graduated machines
Non-self indicating machines
1 kg ≤ Max < 2 kg10 d5 g ≤ d ≤ 10 g100 ≤ n < 4005 g
2 kg ≤ Max < 4 t10 d10 g ≤ d ≤ 10 kg100 ≤ n ≤ 400 Max400
2 kg ≤ Max ≤ 10 t10 d5 g ≤ d ≤ 10 kg400 ≤ n ≤ 1 000d
4 t ≤ Max10 d20 kg ≤ d200 ≤ n < 400 Max400
8 t ≤ Max10 d20 kg ≤ d400 ≤ n ≤ 1 000d
Self and semi-self indicating machines
1 kg ≤ Max ≤ 10 t10 d5 g ≤ d ≤ 10 kg100 ≤ n ≤ 1 000d
4 t ≤ Max10 d20 kg ≤ d200 ≤ n ≤ 1 000d