# The Weighing Equipment (Non-automatic Weighing Machines) Regulations 1988, Paragraph 3


In each weighing mode of a machine each of the tare, weight indicating and printing devices operable in that mode has an associated verification scale interval. In a different weighing mode the same devices may have different verification scale intervals. When testing a machine it is therefore necessary to determine the verification scale interval for each device in each of the weighing modes in which it is operable.

---
Source: https://www.legislation.gov.uk/uksi/1988/876/schedule/2/paragraph/3 (the official version)
Page: https://openlegislation.uk/weighing-equipment-non-automatic-weighing-machines-regulations-1988/schedule-2/paragraph-3