# The Weighing Equipment (Non-automatic Weighing Machines) Regulations 2000, Paragraph 3

Extent: E+W+S

In each weighing mode of a machine each of the tare, weight indicating and printing devices operable in that mode has an associated verification scale interval. In a different weighing mode the same devices may have different verification scale intervals. When testing a machine it is therefore necessary to determine the verification scale interval for each device in each of the weighing modes in which it is operable.

---
Source: https://www.legislation.gov.uk/uksi/2000/932/schedule/1/paragraph/3 (the official version)
Page: https://openlegislation.uk/weighing-equipment-non-automatic-weighing-machines-regulations-2000/schedule-1/paragraph-3
Contains public sector information licensed under the Open Government Licence v3.0. Source: legislation.gov.uk, The National Archives.

