# The Weights and Measures (Local and Working Standard Capacity Measures and Testing Equipment) Regulations 1990, Schedule 1: DISPLACEMENT PLUNGERS


Nominal volume
Limit of error
not exceeding 2 ml
0.1 ml
over
2 ml but not exceeding 25 ml
0.2 ml
over
25 ml but not exceeding 50 ml
0.3 ml
over
50 ml but not exceeding 100 ml
0.4 ml
over
100 ml but not exceeding 125 ml
0.5 ml
over
125 ml but not exceeding 150 ml
0.6 ml
over
150 ml but not exceeding 175 ml
0.7 ml
over
175 ml but not exceeding 250 ml
0.8 ml
over
250 ml but not exceeding 500 ml
1.0 ml

---