OpenLegislation

Regulation 7

Original text. Later amendments are not shown.

Testing equipment consisting of weighing equipment used for testing working standard weights, test weights and egg grading machine test poises shall comply with the following requirements:

(a)

the discrimination threshold of the testing equipment used shall not exceed one-fifth of the relevant amount specified in Tables 1 to 6 in Schedule 2 to these Regulations as the limit of error for the weight being tested, or, in the case of an egg grading machine test poise, 7 mg, and

(b)

the repeatability of the testing equipment shall be such that the 95 per cent. confidence interval of a single reading does not exceed one-fifth of the relevant amount specified in Tables 1 to 6 in Schedule 2 to these Regulations as the limit of error for the weight being tested, or, in the case of an egg grading machine test poise, 7 mg.