Paragraph 4 Aerial and feeder
Aerial
The aerial shall consist of a dipole of a length not greater than 3 metres nor less than 2 metres, which shall be supported so that its centre is not less than 2 metres above the base of the support when a measurement of field-strength is made.
Feeder
The aerial shall be connected to the aerial input terminals of the apparatus by a twin balanced and screened feeder of a nominal characteristic impedance of 75 ohms. The feeder shall be led at right angles from the dipole for a distance of at least 1 metre.
Balance/Unbalance ratio
The balance/unbalance ratio at the aerial end of the feeder shall be not less than 20 db when measured as follows:—
A generator of internal impedance R, where R is not greater than 5 ohms, shall be connected to the feeder and measuring apparatus as shown in Figure 2(a) and as shown in Figure 2(b) in turn. The ratio e1/e2 of the generator e.m.f.'s which produce reference deflection of the meter in the unbalanced connection, (e1 figure 2(a)) and the balanced connection (e2 figure 2(b)) respectively, shall be taken as the balance/unbalance ratio.